Live Status\Incident History\Studios outage
Minor outage
Studios outage
Affects Platform Cloud app
- Resolved
The issue was resolved at 17:05 UTC on September 10, 2026. Restarting an affected Studio is safe and restores normal operation. No other action is required.
- Identified
Between approximately 13:00 and 17:05 UTC on September 10, 2026, Studios in Seqera Cloud were unavailable. New Studios failed to start with a connection error, and Studios that were already running were stopped. The cause was a rotation of an internal authentication key: the Studios connect service continued to verify session tokens against the previous key until it was restarted. Nextflow runs and the rest of the Platform were unaffected. Studios stopped during this period cannot resume on their own. Restarting an affected Studio is safe and restores normal operation. No other action is required.